Calibration of electric thermometers

The laboratory performs accredited calibrations of electric thermometers, including electronic thermometers and temperature recorders. All measurements are carried out in accordance with the requirements of ISO/IEC 17025, ensuring the highest quality and reliability of results.

Point type Number of points Temperature measuring points [°C] Calibration price
Custom temperature measuring points 1 −40… +150 €25
2 −40… +150 €40
3 −40… +150 €50
4 −40… +150 €65
5 −40… +150 €75
6 −40… +150 €90
7 −40… +150 €100
8 −40… +150 €115
Predefined temperature measuring points 3 2 / 5 /8 €40
−20 / 0 / 20 €45
4 / 60 / 100 €45
5 −20 / 0 / 20 / 60 / 100 €70
2 / 4 / 60 / 70 / 100 €70
Custom temperature measuring points
1 point (−40…+150 °C)€25
2 points (−40…+150 °C)€40
3 points (−40…+150 °C)€50
4 points (−40…+150 °C)€65
5 points (−40…+150 °C)€75
6 points (−40…+150 °C)€90
7 points (−40…+150 °C)€100
8 points (−40…+150 °C)€115
Predefined temperature measuring points
3 points (2 /5 / 8 °C)€40
3 points (−20 / 0 / 20 °C)€45
3 points (4 / 60 / 100 °C)€45
5 points (−20 / 0 / 20 / 60 / 100 °C)€70
5 points (2 / 4 / 60 / 70 / 100 °C)€70
Item / Service Price
Battery replacement €3
Calibration Certificate – Paper Version €7
Custom temperature measuring points
1 point (−40…+150 °C)€25
2 points (−40…+150 °C)€40
3 points (−40…+150 °C)€50
4 points (−40…+150 °C)€65
5 points (−40…+150 °C)€75
6 points (−40…+150 °C)€90
7 points (−40…+150 °C)€100
8 points (−40…+150 °C)€115
Predefined temperature measuring points
3 points (2 /5 / 8 °C)€40
3 points (−20 / 0 / 20 °C)€45
3 points (4 / 60 / 100 °C)€45
5 points (−20 / 0 / 20 / 60 / 100 °C)€70
5 points (2 / 4 / 60 / 70 / 100 °C)€70
Point type Number of points Temperature measuring points [°C] Calibration price
Custom temperature measuring points 1 −40… +150 €25
2 −40… +150 €40
3 −40… +150 €50
4 −40… +150 €65
5 −40… +150 €75
6 −40… +150 €90
7 −40… +150 €100
8 −40… +150 €115
Predefined temperature measuring points 3 2 / 5 /8 €40
−20 / 0 / 20 €45
4 / 60 / 100 €45
5 −20 / 0 / 20 / 60 / 100 €70
2 / 4 / 60 / 70 / 100 €70
Custom temperature measuring points
1 point (−40…+150 °C)€25
2 points (−40…+150 °C)€40
3 points (−40…+150 °C)€50
4 points (−40…+150 °C)€65
5 points (−40…+150 °C)€75
6 points (−40…+150 °C)€90
7 points (−40…+150 °C)€100
8 points (−40…+150 °C)€115
Predefined temperature measuring points
3 points (2 /5 / 8 °C)€40
3 points (−20 / 0 / 20 °C)€45
3 points (4 / 60 / 100 °C)€45
5 points (−20 / 0 / 20 / 60 / 100 °C)€70
5 points (2 / 4 / 60 / 70 / 100 °C)€70
Item / Service Price
Battery replacement €3
Calibration Certificate – Paper Version €7

Submitting an object for calibration

Accredited calibration of electric thermometers, including electronic ones, in the range of -40°C to 150°C

Austria

ÖNORM EN ISO/IEC 17025
Allgemeine Anforderungen an die Kompetenz von Prüf- und Kalibrierlaboratorien

Germany

DIN EN ISO/IEC 17025
Allgemeine Anforderungen an die Kompetenz von Prüf- und Kalibrierlaboratorien

Estonia

EVS-EN ISO/IEC 17025
Katse- ja kalibreerimislaborite kompetentsuse üldnõuded

Lithuania

LST EN ISO/IEC 17025
Bendrieji tyrimų, bandymų ir kalibravimo laboratorijų kompetencijos reikalavimai

Latvia

LVS EN ISO/IEC 17025
Testēšanas un kalibrēšanas laboratoriju kompetences vispārīgās prasības

Czech Republic

ČSN EN ISO/IEC 17025
Všeobecné požadavky na kompetenci zkušebních a kalibračních laboratoří

Slovakia

STN EN ISO/IEC 17025
Všeobecné požiadavky na kompetentnosť skúšobných a kalibračných laboratórií

Hungary

MSZ EN ISO/IEC 17025
Vizsgáló- és kalibrálólaboratóriumok felkészültségének általános követelményei

Denmark

DS/EN ISO/IEC 17025
Generelle krav til prøvnings- og kalibreringslaboratoriers kompetence

Finland

SFS-EN ISO/IEC 17025
Testaus- ja kalibrointilaboratorioiden pätevyys. Yleiset vaatimukset

Norway

NS-EN ISO/IEC 17025
Generelle krav til prøvings- og kalibreringslaboratoriers kompetanse

Sweden

SS-EN ISO/IEC 17025
Allmänna kompetenskrav för provnings- och kalibreringslaboratorier

Croatia

HRN EN ISO/IEC 17025
Opći zahtjevi za osposobljenost ispitnih i umjernih laboratorija

Bulgaria

BDS EN ISO/IEC 17025
Общи изисквания за компетентността на лаборатории за изпитване и калибриране

Romania

SR EN ISO/IEC 17025
Cerințe generale pentru competența laboratoarelor de încercări și etalonări

Slovenia

SIST EN ISO/IEC 17025
Splošne zahteve za usposobljenost preskuševalnih in kalibracijskih laboratorijev

Calibration of thermometers – our offer

We offer comprehensive calibration of electric and electronic thermometers – from standard single-point measurements to complete calibration packages at multiple temperature points. This includes:

  • Calibration of thermometers with resistance and thermistor sensors
  • Calibration of temperature recorders and thermometers with built-in and external sensors
  • Calibration in the range of -40°C to 150°C, at any temperature points
  • Issuance of a calibration certificate accredited by the Polish Centre for Accreditation, ensuring measurement consistency and reliability of results

Address for sending objects for calibration:

Łukasiewicz Research Network - Poznań Institute of Technology (Centre for Laboratory Testing),
Laboratory for Heat Treatment and Metrology,
14 Jana Pawła II Street,
61-139 Poznań, Poland

What does obtaining accreditation mean in practice?

International recognition – our certificates are recognized worldwide.

Proven reliability – the highest quality of our services is confirmed by an independent, external accreditation body.

Process security – you work with a partner with proven procedures, which guarantees reliable results on which you can base your business activities.

Precision – we ensure measurement consistency with national measurement standards. 

A research institute with a practical approach

We combine scientific knowledge with business expectations, treat each order individually, and provide full support during the service delivery process.

A team of
experienced experts

Numerous projects for the most demanding customers.

In accordance
with standards

We work in accordance with international standards and our activities are subject to regular audits.

Our specializations in calibration:

Calibration of electric thermometers

Calibration of temperature recorders

Calibration of electronic thermometers

Calibration certificates with accreditation

Calibration of thermometers with external and built-in sensors

Express calibration services

Knowledge base

Calibration of thermometers is a process in which the readings of a calibrated thermometer are compared with a reference instrument with known measurement uncertainty, under strictly defined metrological conditions.

The purpose of calibration is to determine the metrological characteristics of the device, to determine the measurement error together with the uncertainty, which is documented in the calibration certificate, while maintaining measurement consistency in the reference chain in accordance with ISO/IEC 17025 standard.

  • When the device is used in conditions that are important for safety or quality, e.g., in cold stores, food warehouses, laboratories.
  • After any situation that may affect accuracy, e.g., mechanical damage, sudden temperature changes, intensive use, it is worth considering early calibration.

Calibration of thermometers is beneficial for companies that want to ensure accurate temperature measurements in their processes, especially in industries such as food, pharmaceuticals, research laboratories, and electronics. This obligation stems from quality and hygiene standards such as HACCP, GMP, GLP, and ISO 9001, which require regular inspection and calibration of measuring devices. Calibration helps to meet regulatory and legal requirements, which is important for maintaining production quality and consumer safety.

The certificate is issued under the EA MLA agreement for calibration and confirms the consistency of measurement results with the units of measurement of the International System of Units (SI).

The calibration certificate is a formal “passport” for your measuring instrument. It provides key information that allows you to make informed decisions and guarantees quality in your company.

What will you find inside?

The most important thing is the table of results, which clearly shows:

Measurement error: how much your device’s reading differs from the precise standard. Thanks to this value, you know whether and how much correction should be taken into account in your measurements.
Measurement uncertainty: an indicator of the quality of the calibration itself. It specifies the range within which the actual error lies.

Calibration at any point within the range of -40 °C to 150 °C Net price in PLN
Calibration at any temperature point (from -40 °C to 150 °C)PLN 100.00
Calibration at any two temperature points (from -40 °C to 150 °C)PLN 150.00
Calibration at any 3 temperature points (from -40 °C to 150 °C)PLN 200.00
Calibration at any 4 temperature points (from -40 °C to 150 °C)PLN 250.00
Calibration at 5 arbitrary temperature points (from -40 °C to 150 °C)PLN 300.00
Calibration at any 6 temperature points (from -40 °C to 150 °C)PLN 350.00
Calibration at 7 arbitrary temperature points (from -40 °C to 150 °C)PLN 400.00
Calibration at any 8 temperature points (from -40 °C to 150 °C)PLN 450.00
Packages - calibration at selected points Net price in PLN
Calibration at 3 temperature points - Package (-20 °C, 0°C, 20 °C)PLN 180.00
Calibration at 3 temperature points - Package (2 °C, 5 °C, 8 °C)PLN 160.00
Calibration at 3 temperature points - Package (4 °C, 60 °C, 100 °C)PLN 180.00
Calibration at 5 temperature points - Package (-20 °C, 0 °C, 20 °C, 60 °C, 100 °C)PLN 270.00
Calibration at 5 temperature points - Package (2 °C, 4 °C, 60 °C, 70 °C, 100 °C)PLN 270.00
Additional charges
Battery replacementPLN 15.00
Express service (added to the base price)PLN 100.00
Calibration at any point within the range of -40 °C to 150 °C
Calibration at any temperature point (from -40 °C to 150 °C))PLN 100.00
Calibration at any two temperature points (from -40 °C to 150 °C)PLN 150.00
Calibration at any 3 temperature points (from -40 °C to 150 °C)PLN 200.00
Calibration at any 4 temperature points (from -40 °C to 150 °C)PLN 250.00
Calibration at 5 arbitrary temperature points (from -40 °C to 150 °C)PLN 300.00
Calibration at any 6 temperature points (from -40 °C to 150 °C)PLN 350.00
Calibration at 7 arbitrary temperature points (from -40 °C to 150 °C)PLN 400.00
Calibration at any 8 temperature points (from -40 °C to 150 °C)PLN 450.00
Packages - calibration at selected points
Calibration at 3 temperature points - Package (-20 °C, 0°C, 20 °C)PLN 180.00
Calibration at 3 temperature points - Package (2 °C, 5 °C, 8 °C)PLN 160.00
Calibration at 3 temperature points - Package (4 °C, 60 °C, 100 °C)PLN 180.00
Calibration at 5 temperature points - Package (-20 °C, 0 °C, 20 °C, 60 °C, 100 °C)PLN 270.00
Calibration at 5 temperature points - Package (2 °C, 4 °C, 60 °C, 70 °C, 100 °C)PLN 270.00
Additional charges
Battery replacementPLN 15.00
Express service (added to the base price)PLN 100.00

To submit an object for calibration, fill in the fields below and send the form “FO-PW-BLL-03_agreements_with_customer” as an attachment.

    More about personal data protection
    Dawid Kuciarski, zdjęcie portretowe eksperta Łukasiewicz - PIT

    Our expert:

    Dawid Kuciarski

    Phone: +48 887 357 166 

    E-mail: dawid.kuciarski@pit.lukasiewicz.gov.pl 

    Stages of calibration service

    Submitting an object for calibration – agreeing the details of the order with the customer

    Delivery of the device to the Laboratory 

    Conditioning of the object – equalizing the temperature of the device by storing it in the Laboratory room

    Acceptance of the object – verification of suitability for calibration

    Calibration – comparison of the readings of a calibrated thermometer with a standard

    Issuance of a calibration certificate – in electronic or paper form

    Collection of the device by the customer

    FAQ

    Accreditation is a formal confirmation of the competence and technical capabilities of entities such as laboratories, inspection bodies, and certification bodies. PCA, as the only national accreditation body, operates on the basis of legal regulations and assesses whether a given entity meets the relevant norms and standards. PCA accreditation is proof that an entity has undergone a rigorous assessment and is competent in its field. In Poland, the only institution authorized to grant accreditation is the Polish Center for Accreditation.

    A statement of conformity is formal information from a laboratory that a test or calibration result meets specified requirements/specifications, developed in accordance with an accepted decision rule and, where applicable, taking into account measurement uncertainty. ILAC G8:09/2019 “Guidelines on Decision Rules and Statements of Conformity” specifies how laboratories should formulate statements of conformity with specifications in relation to test or calibration results, taking into account measurement uncertainty and established decision rules.

    The calibration points of a thermometer should refer to its measuring range and be reflected in its actual operating ranges. Thus, if a thermometer with an operating range of -40 °C to 150 °C is used, for example, exclusively to measure the temperature in a dryer with a range of 20 °C to 150 °C, it is worth considering calibration at positive temperatures, e.g., 20 °C, 50 °C, 100 °C, 125 °C, 150 °C. If the thermometer is used exclusively in cold rooms with a range of -30 °C to 0 °C, it is worth considering calibration at temperatures equal to and below 0 degrees, e.g., 0 °C, -10 °C, -20 °C, -30 °C. If we cannot precisely specify the operating conditions of the thermometer, it is worth considering calibrating the thermometer at the lowest temperature of its operating range, at 0 °C, the highest temperature of the range, and at temperature points between the above.