Calibration of electric thermometers
The laboratory performs accredited calibrations of electric thermometers, including electronic thermometers and temperature recorders. All measurements are carried out in accordance with the requirements of PN-EN ISO/IEC 17025, ensuring the highest quality and reliability of results.
ACCREDITED SERVICES
What is thermometer calibration?
Calibration of thermometers is a process in which the readings of a calibrated thermometer are compared with a reference instrument with known measurement uncertainty, under strictly defined metrological conditions.
The purpose of calibration is to determine the metrological characteristics of the device, to determine the measurement error together with the uncertainty, which is documented in the calibration certificate, while maintaining measurement consistency in the reference chain in accordance with the PN-EN ISO/IEC 17025 standard.
When is it worth calibrating thermometers?
- When the device is used in conditions that are important for safety or quality, e.g., in cold stores, food warehouses, laboratories.
- After any situation that may affect accuracy, e.g., mechanical damage, sudden temperature changes, intensive use, it is worth considering early calibration.
Who uses thermometer calibration?
Calibration of thermometers is beneficial for companies that want to ensure accurate temperature measurements in their processes, especially in industries such as food, pharmaceuticals, research laboratories, and electronics. This obligation stems from quality and hygiene standards such as HACCP, GMP, GLP, and ISO 9001, which require regular inspection and calibration of measuring devices. Calibration helps to meet regulatory and legal requirements, which is important for maintaining production quality and consumer safety.
Calibration of thermometers – our offer
We offer comprehensive calibration of electric and electronic thermometers – from standard single-point measurements to complete calibration packages at multiple temperature points. This includes::
- Calibration of thermometers with resistance and thermistor sensors
- Calibration of temperature recorders and thermometers with built-in and external sensors
- Calibration in the range of -40°C to 150°C, at any temperature points
- Issuance of a PCA-accredited calibration certificate, ensuring measurement consistency and reliability of results
Accredited calibration of electric thermometers, including electronic ones, in the range of -40°C to 150°C
Our specializations in calibration:
Calibration of electric thermometers
Calibration of temperature recorders
Calibration of electronic thermometers
Calibration certificates with accreditation
Calibration of thermometers with external and built-in sensors
Express calibration services
What does obtaining accreditation mean in practice?
International recognition – these certificates are recognized worldwide.
Proven reliability – the highest quality of our services is confirmed by an independent, external accreditation body.
Process security – you work with a partner with proven procedures, which guarantees reliable results on which you can base your business activities.
Precision – we ensure measurement consistency with national measurement standards. The results refer to national metrological standards.


What does a calibration certificate look like?
The certificate is issued under the EA MLA agreement for calibration and confirms the consistency of measurement results with the units of measurement of the International System of Units (SI).
The calibration certificate is a formal “passport” for your measuring instrument. It provides key information that allows you to make informed decisions and guarantees quality in your company.
What will you find inside?
The most important thing is the table of results, which clearly shows:
Measurement error: how much your device’s reading differs from the precise standard. Thanks to this value, you know whether and how much correction should be taken into account in your measurements.
Measurement uncertainty: an indicator of the quality of the calibration itself. It specifies the range within which the actual error lies.
A research institute with a practical approach
We combine scientific knowledge with business expectations, treat each order individually, and provide full support during the service delivery process.
A team of
experienced experts
Numerous projects for the most demanding customers
In accordance
with standards
We work in accordance with international standards and our activities are subject to regular audits.
Calibration service price list
| Calibration at any point within the range of -40 °C to 150 °C | Net price in PLN |
|---|---|
| Calibration at any temperature point (from -40 °C to 150 °C) | PLN 100.00 |
| Calibration at any two temperature points (from -40 °C to 150 °C) | PLN 150.00 |
| Calibration at any 3 temperature points (from -40 °C to 150 °C) | PLN 200.00 |
| Calibration at any 4 temperature points (from -40 °C to 150 °C) | PLN 250.00 |
| Calibration at 5 arbitrary temperature points (from -40 °C to 150 °C) | PLN 300.00 |
| Calibration at any 6 temperature points (from -40 °C to 150 °C) | PLN 350.00 |
| Calibration at 7 arbitrary temperature points (from -40 °C to 150 °C) | PLN 400.00 |
| Calibration at any 8 temperature points (from -40 °C to 150 °C) | PLN 450.00 |
| Packages - calibration at selected points | Net price in PLN |
| Calibration at 3 temperature points - Package (-20 °C, 0°C, 20 °C) | PLN 180.00 |
| Calibration at 3 temperature points - Package (2 °C, 5 °C, 8 °C) | PLN 160.00 |
| Calibration at 3 temperature points - Package (4 °C, 60 °C, 100 °C) | PLN 180.00 |
| Calibration at 5 temperature points - Package (-20 °C, 0 °C, 20 °C, 60 °C, 100 °C) | PLN 270.00 |
| Calibration at 5 temperature points - Package (2 °C, 4 °C, 60 °C, 70 °C, 100 °C) | PLN 270.00 |
| Additional charges | |
| Battery replacement | PLN 15.00 |
| Express service (added to the base price) | PLN 100.00 |
| Wzorcowanie w dowolnych punktach w zakresie -40 °C do 150 °C | |
|---|---|
| Wzorcowanie w 1 dowolnym punkcie temperaturowym (od -40 °C do 150 °C) | 100,00 zł |
| Wzorcowanie w 2 dowolnych punktach temperaturowych (od -40 °C do 150 °C) | 150,00 zł |
| Wzorcowanie w 3 dowolnych punktach temperaturowych (od -40 °C do 150 °C) | 200,00 zł |
| Wzorcowanie w 4 dowolnych punktach temperaturowych (od -40 °C do 150 °C) | 250,00 zł |
| Wzorcowanie w 5 dowolnych punktach temperaturowych (od -40 °C do 150 °C) | 300,00 zł |
| Wzorcowanie w 6 dowolnych punktach temperaturowych (od -40 °C do 150 °C) | 350,00 zł |
| Wzorcowanie w 7 dowolnych punktach temperaturowych (od -40 °C do 150 °C) | 400,00 zł |
| Wzorcowanie w 8 dowolnych punktach temperaturowych (od -40 °C do 150°C) | 450,00 zł |
| Pakiety - wzorcowanie w wybranych punktach | |
| Wzorcowanie w 3 punktach temperaturowych - Pakiet (-20 °C, 0 °C, 20 °C) | 180,00 zł |
| Wzorcowanie w 3 punktach temperaturowych - Pakiet (2 °C, 5 °C, 8 °C) | 160,00 zł |
| Wzorcowanie w 3 punktach temperaturowych - Pakiet (4°C, 60 °C,100 °C) | 180,00 zł |
| Wzorcowanie w 5 dowolnych punktach temperaturowych (-20 °C, 0 °C, 20 °C, 60 °C, 100 °C) | 270,00 zł |
| Wzorcowanie w 5 dowolnych punktach temperaturowych (2 °C, 4 °C, 60 °C, 70 °C, 100°C) | 270,00 zł |
| Dodatkowe opłaty | |
| Wymiana baterii | 15,00 zł |
| Usługa ekspresowa (doliczana do ceny podstawowej) | 100,00 zł |
Submitting an object for calibration
Standard points
In the “FO-PW-BLL-03_agreements_with_customer” form, in the “Basic information about the calibration object” table, in point 7 “Calibration points in °C,” select one of the available options from the drop-down list. For non-standard points, enter the desired calibration point temperatures, separating
them with a “/” sign. The calibration temperature range is from -40 °C to 150 °C.
Non-standard points
In the “FO-PW-BLL-03_ustalenia_z_klientem” form, in the “Basic information about the calibration object” table, in point 7 “Calibration points in °C,” enter the desired calibration point temperatures, separating them with a “/” sign. If you select standard points, choose one of the available options from the drop-down list. The calibration temperature range is from -40 °C to 150 °C.
Address for sending objects for calibration:
Łukasiewicz Reserach Network - Poznań Institute of Technology (Centre for Laboratory Testing),
Laboratory for Metrology,
14 Jana Pawła II Street,
61-139 Poznań, Poland
To submit an object for calibration, fill in the fields below and send the form “FO-PW-BLL-03_ustalenia_z_klientem” as an attachment.
Stages of calibration service
Submitting an object for calibration – agreeing the details of the order with the customer
Delivery of the device to the Laboratory – in person or by mail
Conditioning of the object – equalizing the temperature of the device by storing it in the Laboratory room
Acceptance of the object – verification of suitability for calibration
Calibration – comparison of the readings of a calibrated thermometer with a standard
Issuance of a calibration certificate – in electronic or paper form
Collection of the device by the customer – in person or by mail
FAQ
What is accreditation in relation to calibration?
Accreditation is a formal confirmation of the competence and technical capabilities of entities such as laboratories, inspection bodies, and certification bodies. PCA, as the only national accreditation body, operates on the basis of legal regulations and assesses whether a given entity meets the relevant norms and standards. PCA accreditation is proof that an entity has undergone a rigorous assessment and is competent in its field. In Poland, the only institution authorized to grant accreditation is the Polish Center for Accreditation.
What is a statement of compliance?
A statement of conformity is formal information from a laboratory that a test or calibration result meets specified requirements/specifications, developed in accordance with an accepted decision rule and, where applicable, taking into account measurement uncertainty. ILAC G8:09/2019 “Guidelines on Decision Rules and Statements of Conformity” specifies how laboratories should formulate statements of conformity with specifications in relation to test or calibration results, taking into account measurement uncertainty and established decision rules.
How to select calibration points?
The calibration points of a thermometer should refer to its measuring range and be reflected in its actual operating ranges. Thus, if a thermometer with an operating range of -40 °C to 150 °C is used, for example, exclusively to measure the temperature in a dryer with a range of 20 °C to 150 °C, it is worth considering calibration at positive temperatures, e.g., 20 °C, 50 °C, 100 °C, 125 °C, 150 °C. If the thermometer is used exclusively in cold rooms with a range of -30 °C to 0 °C, it is worth considering calibration at temperatures equal to and below 0 degrees, e.g., 0 °C, -10 °C, -20 °C, -30 °C. If we cannot precisely specify the operating conditions of the thermometer, it is worth considering calibrating the thermometer at the lowest temperature of its operating range, at 0 °C, the highest temperature of the range, and at temperature points between the above.
Our experts:
Dawid Kuciarski
Phone: +48 887 357 166
E-mail: dawid.kuciarski@pit.lukasiewicz.gov.pl
Łukasiewicz Research Network – Poznań Institute of Technology (Centre for Laboratory Testing), Laboratory for Metrology, 14 Jana Pawła II Street, 61-139 Poznań, Poland
Jarosław Dropik
Phone: +48 61 657 05 55 (wew. 182)
E-mail: jaroslaw.dropik@pit.lukasiewicz.gov.pl
Łukasiewicz Research Network – Poznań Institute of Technology (Centre for Laboratory Testing), Laboratory for Metrology, 14 Jana Pawła II Street, 61-139 Poznań, Poland